Cart

Added to cart

Go to cart

Your order qualifies for free 2-day shipping and easy returns

Thermal Camera for Science Applications

FLIR T530 (Science)

Model: FLIR T530 14° (Science) Go to Product Support
product image

The FLIR T530 thermal imaging camera has the features researchers, engineers, and product developers need to accurately measure thermal events and spot potential design flaws. This uncooled, 320 × 240 (76,800 pixel) thermal camera produces crisp, vibrant imagery that can be enhanced through UltraMax® technology for up to 307,200 pixel thermal resolution. Measure components down to 103 µm/pixel spot size with the optional Macro Mode or down to 49 µm/pixel with a 2x macro lens. Thanks to the award-winning ergonomic design and intuitive, rapid-response interface, the T530 can increase efficiency and help reduce test times. When coupled with Research Studio software, these cameras help researchers perform in-depth analysis and share data quickly.

Sales Contact Contact Sales
  • Precise Temperature Measurement

    The T530 offers the temperature sensitivity needed to detect differences smaller than 0.03°C and an optional measurement range to quantify heat generation up to 1200°C.

  • Efficient Testing and Reporting

    Set up and start testing quickly with the intuitive graphic user interface and streamlined user features and analysis tools.

  • Intuitive Thermal Imagery

    Build client trust through sharply-focused, brilliant images that are also easy for non-experts to interpret.

Contact Sales

Want more information on this product?

Call (866) 477-3687 to speak with a knowledgeable specialist.

Specifications
IR Resolution
320 × 240 (76,800 pixels)
Resolution
640 × 480 pixels (VGA)
Spectral Range
7.5 - 14.0 µm
f-number
1.5, 14°
Thermal Sensitivity/NETD
<50 mK, 14° @ +30°C (+86°F)
Focus
Continuous with laser distance meter (LDM), one- shot LDM, one-shot contrast, manual
Imaging & Optical
Camera software update
Using USB cable or SD card
Color
Black
Color Palettes
Iron, Gray, Rainbow, Arctic, Lava, Rainbow HC
Detector Type and Pitch
Uncooled microbolometer, 17 µm
Digital Camera
5 MP, with built-in LED photo/video lamp
Digital Camera FOV
53° × 41°
Digital Zoom
1-4x continuous
Field of View
14° × 10°
f-number
1.5, 14°
Focal Length
29 mm (1.41 in.), 14°
Focus
Continuous with laser distance meter (LDM), one- shot LDM, one-shot contrast, manual
Gallery
Yes
Image Frequency
30 Hz
IR Resolution
320 × 240 (76,800 pixels)
Laser Alignment
Position is automatically displayed on the infrared image
Lens Identification
Automatic
Minimum Focus Distance
1.0 m (3.28 ft.), 14°
Minimum Focus Distance with MSX
1.0 m (3.28 ft.), 14°
Non-radiometric IR video streaming
H.264 or MPEG-4 over Wi-Fi MJPEG over UVC or Wi-Fi
Picture-in-Picture
Resizable and movable
Radiometric IR video recording
Real-time radiometric recording (.csq)
Radiometric IR video streaming
Over UVC
Resolution
640 × 480 pixels (VGA)
Spatial resolution (IFOV)
0.75 mrad/pixel, 14°
Spectral Range
7.5 - 14.0 µm
Thermal Sensitivity/NETD
<50 mK, 14° @ +30°C (+86°F)
UltraMax
Quadruples pixel count; activated in menu and processed in FLIR Tools
Video Lamp
Built-in LED light
Viewfinder
No
Visual Image
Yes
Visual Video Recording
H.264 to memory card
Visual Video Streaming
Yes
Measurement & Analysis
Accuracy
±2°C (±3.6°F) or ±2% of reading
Automatic hot & cold detection
Automatic maximum/minimum markers within area
Color Alarm (Isotherm)
•Above •Below •Interval •Condensation (moisture/humidity/dewpoint) •Insulation
Difference Temperature
Yes
Emissivity Correction
Yes, variable from 0.01 to 1.0 or selected from materials list
Measurement Corrections
Yes
Measurement Function Alarm
Audible/visual alarms (above/below) on any selected measurement function
Measurement Presets
•No measurements •Center spot •Hot spot •Cold spot •User preset 1 •User preset 2
Object Temperature Range
-20°C to 120°C (-4°F to 248°F) 0°C to 650°C (32°F to 1202°F) Optional Calibration: 300°C to 1200°C (572°F to 2192°F)
Reference Temperature
Yes
Communication & Data Storage
Audio
Microphone and speaker for voice annotation of images
Communication Interfaces
USB 2.0, Bluetooth®, Wi-Fi
Image File Format
Standard JPEG with measurement data included
METERLiNK
Wireless connection (Bluetooth®) to: FLIR meters with METERLiNK
METERLiNK - Bluetooth
Communication with headset and external sensors
Storage Media
Removable SD card
USB
USB Type-C: data transfer/video/power
USB - Standard
USB 2.0 High Speed
Video Out
DisplayPort over USB Type-C
General
Housing material
PCABS with TPE, magnesium
Laser Pointer
Class 2, 0.05–40 m (0.16–131 ft.) ±1% of measured distance
Packaging
Infrared camera with lens, 2 batteries, battery charger, hard transport case, lanyards, front lens cap, power supplies, printed documentation, SD card (8 GB), cables (USB 2.0 A to USB Type-C, USB Type-C to HDMI, USB Type-C to USB Type-C)
Packaging Size
500 × 190 × 370 mm (19.7 × 7.5 × 14.6 in.)
Size (L x W x H)
Lens horisontal: 140 × 201.3 × 167.3 mm (5.5 × 7.9 × 6.6 in.)
User Interface
Display
4", 640 × 480 pixel touchscreen LCD with auto-rotation
Display Technology
IPS
Languages
21
Text
Predefined list or touchscreen keyboard
Touch Screen
Optically bonded PCAP
Voice
60 sec. recording added to still images or video via built-in mic (has speaker) or via Bluetooth®
Power
Battery operating time
Approx. 4 hours at 25°C (77°F) ambient temperature and typical use
Battery type
Li-ion battery, charged in camera or on separate charger
Battery voltage
3.6 V
Battery weight
195 g (6.89 oz.)
Charging system
In camera (AC adapter or 12 V from a vehicle) or two-bay charger
Charging Temperature
0°C to 45°C (32°F to 113°F), except for the Korean market: 10°C to 45°C (50°F to 113°F)
External Power Operation
AC adapter 90–260 V AC (50/60 Hz) or 12 V from a vehicle (cable with standard plug, optional)
Power Management
Automatic shut-down and sleep mode
Environmental & Certifications
EMC
•ETSI EN 301 489-1 (radio) •ETSI EN 301 489-17 •EN 61000-6-2 (immunity) •EN 61000-6-3 (emission) •FCC 47 CFR Part 15 Class B (emission)
Humidity (Operating and Storage)
IEC 60068-2-30/24 hours, 95% relative humidity, 25–40°C (77–104°F)/2 cycles
Operating Temperature Range
–15°C to 50°C (5°F to 122°F)
Radio Spectrum
•ETSI EN 300 228 •FCC Part 15.249 •RSS-247 Issue 2
Safety
EN/UL/CSA/PSE 60950-1
Storage Temperature Range
–40°C to 70°C (-40°F to 158°F)
Tripod Mounting
UNC 1/4"-20
Warranty
http://www.flir.com/warranty/
Related Documents
Export Restrictions

Export Restrictions

The information contained in this page pertains to products that may be subject to the International Traffic in Arms Regulations (ITAR) (22 C.F.R. Sections 120-130) or the Export Administration Regulations (EAR) (15 C.F.R. Sections 730-774) depending upon specifications for the final product; jurisdiction and classification will be provided upon request.

FLIR T530 (Science) - Model: FLIR T530 14° (Science)

Change Selection