The FLIR A65 is a thermal imaging temperature sensor for process control/quality assurance, fire prevention, and condition monitoring that offers comprehensive visual temperature monitoring. The A65 integrates seamlessly into existing systems and provides temperature linear output through GenICam™ compliant software.
- Products
- Industrial
- Fixed Thermal Cameras
- FLIR A65
Added to cart
-
Affordable and Compact
At just 4.1 × 1.9 × 1.8 in, the A65 brings thermal imaging to your smallest spaces at an affordable price.
-
Plug-and-Play
Easy setup thanks to GigE Vision and GenICam compliance and GigE Vision lockable connector.
-
Connect Multiple Cameras
Synchronize between multiple cameras for greater coverage and communication, or for stereoscopic applications.
Temperature Sensing With the Advantage of Image Quality
The FLIR A65 produces stunning 327,680 pixel thermal images that are low noise, and can show temperature differences as small as 50 mK. This allows you to easily track temperature changes, whether your application is process control/quality assurance, condition monitoring, or fire prevention.
Contact Sales
Want more information on this product?
Call (866) 477-3687 to speak with a knowledgeable specialist.
Specifications
- Digital I/O connector type
- 12-pole M12 connector (shared with Digital Synchronization and External power)
- Digital Inputs
- 1× opto-isolated, "0" <1.2 VDC, "1" = 2–25 VDC.
- Digital Output Purpose
- General purpose output to ext. device (programmatically set)
- Digital Outputs
- 1× opto-isolated, 2–40 VDC, max 185 mA
- EMC
- EN 61000-6-2 (Immunity) EN 61000-6-3 (Emission) FCC 47 CFR Part 15 Class B (Emission)
- f-number
- 1.25
- Image Frequency
- 30 Hz
- Thermal Sensitivity/NETD
- <0.05°C @ 30°C (86°F) / 50 mK
- Accuracy
- ±5°C (±9°F) or ±5% of reading
Communication & Data Storage
- Digital I/O connector type
- 12-pole M12 connector (shared with Digital Synchronization and External power)
- Digital I/O isolation voltage
- 500 VRMS
- Digital I/O supply voltage
- 2–40 VDC, max 200 mA
- Digital input purpose
- General Purpose
- Digital Inputs
- 1× opto-isolated, "0" <1.2 VDC, "1" = 2–25 VDC.
- Digital Output Purpose
- General purpose output to ext. device (programmatically set)
- Digital Outputs
- 1× opto-isolated, 2–40 VDC, max 185 mA
- Digital Synchronization Connector Type
- 12-pole M12 connector (shared with Digital I/O and External power)
- Ethernet
- Control and image
- Ethernet Communication
- GigE Vision ver. 1.2 Client API GenICam compliant
- Ethernet Connector Type
- RJ-45
- Ethernet Image Streaming
- 8-bit monochrome @ 30 Hz Signal linear/ DDE Automatic/ Manual Flip H&V 14-bit 640 × 512 pixels @ 30 Hz Signal linear/ DDE Temperature linear GigE Vision and GenICam compatible
- Ethernet Power
- Power over Ethernet, PoE IEEE 802.3af class 0 Power
- Ethernet Protocols
- TCP, UDP, ICMP, IGMP, DHCP, GigEVision
- Ethernet Standard
- IEEE 802.3 / RJ-45
- Ethernet Type
- Gigabit Ethernet
- Synchronization in
- 1×, non-isolated
- Synchronization in - purpose
- Frame sync in to control camera
- Synchronization in - type
- LVC Buffer @3.3V, "0" <0.8 V, "1" >2.0 V.
- Synchronization out
- 1×, non-isolated
- Synchronization out - purpose
- Frame sync out to control another Ax5 camera
- Synchronization Out - type
- LVC Buffer @ 3.3V, "0"=24 MA max, "1"= –24 mA max.
Imaging & Optical
- Detector Pitch
- 17 µm
- Detector Time Constant
- Typical 12 ms
- Detector Type
- Focal plane array (FPA), uncooled VOX microbolometer
- Field of view (FOV)
- 25° × 20° with 25 mm lens
- FLIR Screen-EST Mode
- No
- f-number
- 1.25
- Focal Length
- 25 mm (0.98 in.)
- Focus
- Fixed
- Image Frequency
- 30 Hz
- IR Resolution
- 640 × 512 pixels
- Spatial resolution (IFOV)
- 0.68 mrad
- Spectral Range
- 7.5–13 µm
- Thermal Sensitivity/NETD
- <0.05°C @ 30°C (86°F) / 50 mK
Measurement & Analysis
- Accuracy
- ±5°C (±9°F) or ±5% of reading
- Atmospheric transmission correction
- Automatic, based on inputs for distance, atmospheric temperature and relative humidity
- Camera size (L x W x H)
- 107.8 × 49.6 × 46.6 mm (4.2 × 1.9 × 1.8 in.)
- Emissivity Correction
- Variable from 0.5 to 1.0
- External Optics & Windows Correction
- Automatic, based on input of optics/window transmission and temperature
- Measurement Corrections
- Global object parameters
- Object Temperature Range
- -25°C to 135°C (-13 to 275°F) / –40°C to 550°C (-40 to 1022°F)
- Optics Transmission Correction
- Automatic, based on signals from internal sensors
- Reflected apparent temperature correction
- Automatic, based on input of reflected temperature
General
- Base Mounting
- 4 × M3 thread mounting holes (bottom)
- Housing material
- Magnesium and aluminum
- Package Includes
- Cardboard box, thermal imaging camera with lens, focus adjustment tool, printed documentation, user documentation CD-ROM, FLIR Tools download card
- Weight
- 0.21 kg (0.46 lb.)
Environmental & Certifications
- EMC
- EN 61000-6-2 (Immunity) EN 61000-6-3 (Emission) FCC 47 CFR Part 15 Class B (Emission)
- Encapsulation
- IP 40 (IEC 60529) with base support mounted
- Humidity (Operating and Storage)
- IEC 60068-2-30/24 h 95% relative humidity 25°C to 40°C (77°F to 104°F)
- Operating Temperature Range
- –15°C to 50°C (5°F to 122°F) The operating temperature range assumes that the camera is mounted on the base support (included in the package) or a similar type of heatsink.
- Shock
- 25 g (IEC 60068-2-27)
- Storage Temperature Range
- –40°C to 70°C (–40°F to 158°F)
- Tripod Mounting
- UNC ¼"-20 (on three sides)
- Vibration
- 2 g (IEC 60068-2-6 & MIL-STD810G)
Power
- External Power Connector Type
- 12-pole M12 connector (shared with Digital I/O and Digital Synchronization )
- External Power Operation
- 12/24 VDC, < 3.5 W nominal < 6.0 W absolute max
- Voltage
- Allowed range 10–30 VDC
Related Documents
Export Restrictions
Export Restrictions
The information contained in this page pertains to products that may be subject to the International Traffic in Arms Regulations (ITAR) (22 C.F.R. Sections 120-130) or the Export Administration Regulations (EAR) (15 C.F.R. Sections 730-774) depending upon specifications for the final product; jurisdiction and classification will be provided upon request.
Want more information on this product?
Call (866) 477-3687 to speak with a knowledgeable specialist.